GDM355/365 |
|
Parameter Indicator |
|
Compass heading parameters |
Heading accuracy |
1° |
|
Resolution |
0.1° |
|
|
Pitch measurement range |
±90° |
|
|
Roll measurement range |
±180° |
|
|
Tilt accuracy |
Static0.2° |
|
|
Dynamic0.5° |
||
|
Resolution |
0.1° |
|
|
Tilt compensation angle range |
Roll±180° |
|
|
Pitch<85° |
||
|
Three-axis magnetic field |
Measurement range |
±800uT |
|
Calibration |
Hard iron calibration |
Yes |
|
Soft iron calibration |
Yes |
|
|
Magnetic field interference calibration method |
Planar rotation (2D calibration) |
|
|
Interface characteristics |
Startup delay |
<50ms |
|
Output rate |
5~100Hz(adjustable) |
|
|
Baud rate |
4800to115200baud |
|
|
Output format |
Binary high-performance protocol |
|
|
Power supply |
Supply voltage |
(Default)DC+5V |
|
(Custom)DC9~36V |
||
|
Current (MAX) |
45mA |
|
|
Ideal mode |
35mA |
|
|
Sleep mode |
TBD |
|
|
Environment |
Operating range |
-40℃~+85℃ |
|
Storage temperature |
-40℃~+85℃ |
|
|
Vibration resistance |
2500g |
|
|
Electromagnetic compatibility |
Compliant with EN61000 and GBT17626 |
|
|
Insulation resistance |
≥100megohms |
|
|
Shock resistance |
100g@11ms, triaxial (half-sine wave) |
|
|
Vibration resistance |
10grms/10~1000Hz |
|
|
Dimensions |
PCBA dimensions: L33×W27×H9mm Case dimensions: L55.5×W37×H24mm |
|
|
Cable length/weight |
PCBA trace length: 20cm±3cm Case trace length: 200cm±10cm |
|
|
Weight |
PCBA weight: ≤25g Case package weight: ≤117g (excluding cables) |
|