Dynamic High-Shock-Resistant Tilt Sensor
WDS826FL
Special Dual Axis Tilt Angle Sensor
  • Dual axis inclination measurement
  • Range ±10°
  • Horizontal Installation
  • Resolution 0.0005°
  • Good low-frequency characteristics
Product Introduction


WDS826FL is a dynamic tilt measurement product designed specifically for monitoring the shaking of wind turbine towers. It has excellent low-frequency response characteristics and can effectively capture slowly changing tilt signals, meeting the precise measurement needs in low-frequency dynamic scenarios. Before leaving the factory, the products undergo full temperature range calibration compensation and long-term stability testing to ensure reliable performance indicators are maintained under different working conditions and long-term use cycles.


This product integrates two output protocols, including the industrial standard MODBUS protocol, and comes with dedicated analysis software that can display, record, and analyze measurement data in real-time. The output interface supports RS485, RS422, RS232 optional. Adopting non-contact installation method, it has strong system integration convenience; Users only need to fix the sensor on the surface of the object being measured with screws, and the system can automatically calculate the horizontal angle, making it easy to use. The product has good resistance to external electromagnetic interference and vibration impact, and is suitable for scenarios such as wind turbine swing monitoring.
Performance Parameters

WDS826FL

Condition

Parameters

Unit

Measure Range

-

±10

°

Measure Axis

-

X Y

Axis

Resolution1)

-

0.0005

°

Measure Accuracy2)

Room Temp.

0.05

°

Zero Temp Coefficient3)

-40~85℃

0.0003

°/℃

Sensitivity Temp.Coefficient4)

-40~85℃

≤50

ppm/℃

Power on Time


<0.5

S

Response Frequency


20

Hz

Output Rate

5Hz / 10Hz / 25Hz / 35Hz / 50Hz / 100Hz Can be set

Output Signal

RS485 / RS232 / RS422 Optional

EMC

According to EN61000 and GBT17626

MTBF

≥98000hour/time

Insulation Resistance

≥100 MΩ

Shockproof

100g@11ms / 3 Axial Direction (Half Sinusoid)

Anti-vibration

10grms / 10~1000Hz

Protection Grade

IP67

Cables

Standard 1 meter long wear-resistant, wide temperature, shielded cable, aviation connector, weight ≤150g

Weight

≤450g (Excluding cable)

1)Resolution: The smallest change in the measured quantity that a sensor can detect and distinguish within its measurement range.

2)Accuracy: The accuracy value obtained by measuring multiple angle points within the measurement range.

3)Zero-point temperature coefficient: The rate of change of the sensor's reading relative to room temperature within its rated operating temperature range when the sensor is at zero.

4)Sensitivity temperature coefficient: The rate of change of the sensor's full-scale reading relative to its full-scale reading at room temperature within its rated operating temperature range as a percentage of temperature.

Product Dimensions