DTS CANOpen |
Unit |
Parameter |
|
|
Measurement Range |
° |
X-tilt ±180°, Y-tilt ±90° |
|
|
Measurement Axis |
axis |
X & Y dual-axis |
|
|
Roll and Pitch Resolution1) |
° |
0.01 |
|
|
Roll and Pitch Static Accuracy @25℃ |
° |
±0.05 |
|
|
Roll and Pitch Dynamic Accuracy (rms) @25℃ |
° |
±0.1 |
|
|
Gyroscope |
Gyroscope Range |
°/s |
±300 |
|
Zero-bias Stability (10s mean) |
°/h |
8.5 |
|
|
Zero-bias Instability (allan) |
°/h |
4.5 |
|
|
Angle Random Walk Coefficient (allan) |
°/sqrt(h) |
0.25 |
|
|
Acceleration |
Acceleration Range |
g |
±4 /±16(Optional) |
|
Bias Stability (10s mean) |
mg |
0.02 |
|
|
Bias Instability (allan) |
mg |
0.005 |
|
|
Velocity Random Walk Coefficient (allan) |
m/s/sqrt(h) |
0.005 |
|
|
Zero-point Temperature Coefficient3)@-40~85℃ |
°/℃ |
±0.01 |
|
|
Sensitivity Temperature Coefficient4)@-40~85℃ |
ppm/℃ |
≤100 |
|
|
Power-on Time |
S |
≤3.5 |
|
|
Response Time |
S |
0.01 |
|
|
Communication Protocol |
- |
CAN Open |
|
|
Electromagnetic Compatibility |
- |
According to EN61000 and GBT17626 |
|
|
Mean Time Between Failures (MTBF) |
Hours/Time |
≥98000 |
|
|
Insulation Resistance |
Megaohm |
≥100 |
|
|
Shock Resistance |
- |
100g@11ms, Triaxial (half-sine wave) |
|
|
Vibration Resistance |
- |
10grms、10~1000Hz |
|
|
Protection Class |
- |
IP67/ IP68(optional) |
|
|
Weight |
g |
Single Connector ≤165g (excluding cable) / Dual Connector ≤180g (excluding cable) |
|
|
1) Resolution: The smallest angular change that the sensor can detect within its effective range, reflecting its ability to monitor minute tilt fluctuations. 2) Accuracy: Calculated by performing multiple repeated measurements (sample size ≥ 16) at a fixed angle under standard ambient temperature (25±5℃), representing the root mean square (RMS) error between the measured and true values, characterizing the sensor's overall measurement deviation. 3) Zero-point temperature coefficient: The ratio of the sensor's output value to temperature change under zero-input conditions, defined as the ratio of the zero-point offset within the rated operating temperature range to the room temperature reference value. 4) Sensitivity temperature coefficient: The stability index of the sensor's full-scale output value with temperature changes, characterizing the drift rate of sensitivity relative to the room temperature reference value within the rated temperature range. |
|||